| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability in the cryptographic logic used by HPE Aruba Networking EdgeConnect SD-WAN Gateways could allow an authenticated remote attacker to gain shell access. Successful exploitation could allow an attacker to execute arbitrary commands on the underlying operating system, potentially leading to unauthorized access and control over the affected systems. |
| The use of a hard-coded cryptographic key was discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software contains a hard-coded AES key used to protect the initial messages of a new KOPS session. |
| Missing cryptographic key commitment in the Amazon S3 Encryption Client for Go may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade Amazon S3 Encryption Client for Go to version 4.0 or later. |
| An issue was discovered in Kaseya Rapid Fire Tools Network Detective through 2.0.16.0. A vulnerability exists in the EncryptionUtil class because symmetric encryption is implemented in a deterministic and non-randomized fashion. The method Encrypt(byte[] clearData) derives both the encryption key and the IV from a fixed, hardcoded input by using a static salt value. As a result, identical plaintext inputs always produce identical ciphertext outputs. This is true for both FIPS and non-FIPS generated passwords. In other words, there is a cryptographic implementation flaw in the password encryption mechanism. Although there are multiple encryption methods grouped under FIPS and non-FIPS classifications, the logic consistently results in predictable and reversible encrypted outputs due to the lack of per-operation randomness and encryption authentication. |
| The Fedora Secure Boot CA certificate shipped with shim in Fedora was expired which could lead to old or invalid signed boot components being loaded. |
| Vulnerability in Best Practical Solutions, LLC's Request Tracker prior to v5.0.8, where the Triple DES (3DES) cryptographic algorithm is used to protect emails sent with S/MIME encryption. Triple DES is considered obsolete and insecure due to its susceptibility to birthday attacks, which could compromise the confidentiality of encrypted messages. |
| This vulnerability exists in AppSamvid software due to the usage of a weaker cryptographic algorithm (hash) SHA1 in user login component. An attacker with local administrative privileges could exploit this to obtain the password of AppSamvid on the targeted system.
Successful exploitation of this vulnerability could allow the attacker to take complete control of the application on the targeted system. |
| A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). Affected devices only provide weak password obfuscation. An attacker with network access could retrieve and de-obfuscate the safety password used for protection against inadvertent operating errors. |
| Missing cryptographic key commitment in the AWS SDK for Ruby may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade AWS SDK for Ruby to version 1.208.0 or later. |
| LangChain4j-AIDeepin is a Retrieval enhancement generation (RAG) project. Prior to 3.5.0, LangChain4j-AIDeepin uses MD5 to hash files, which may cause file upload conflicts. This issue is fixed in 3.5.0. |
| A vulnerability exists in Algo Edge up to 2.1.1 - a previously used (legacy) component of navify® Algorithm Suite. The vulnerability impacts the authentication mechanism of this component and could allow an attacker with adjacent access to the laboratory network and the Algo Edge system to craft valid authentication tokens and access the component. Other components of navify® Algorithm Suite are not affected. |
| Weak algorithm used to sign RPM package. The following products are affected: Acronis Cyber Protect Cloud Agent (Linux) before build 39185, Acronis Cyber Protect 16 (Linux) before build 39938. |
| A vulnerability in the SageMaker Workflow component of aws/sagemaker-python-sdk allows for the possibility of MD5 hash collisions in all versions. This can lead to workflows being inadvertently replaced due to the reuse of results from different configurations that produce the same MD5 hash. This issue can cause integrity problems within the pipeline, potentially leading to erroneous processing outcomes. |
| The AES key utilized in the pairing process between a lock using Sciener firmware and a wireless keypad is not unique, and can be reused to compromise other locks using the Sciener firmware. |
| Missing cryptographic key commitment in the AWS SDK for C++ may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade AWS SDK for C++ to version 1.11.712 or later |
| Certain Anpviz products contain a hardcoded cryptographic key stored in the firmware of the device. This affects IPC-D250, IPC-D260, IPC-B850, IPC-D850, IPC-D350, IPC-D3150, IPC-D4250, IPC-D380, IPC-D880, IPC-D280, IPC-D3180, MC800N, YM500L, YM800N_N2, YMF50B, YM800SV2, YM500L8, and YM200E10 firmware v3.2.2.2 and lower and possibly more vendors/models of IP camera. |
| Use of a Broken or Risky Cryptographic Algorithm vulnerability in Mia Technology Inc. Mia-Med Health Aplication allows Signature Spoofing by Improper Validation.This issue affects Mia-Med Health Aplication: before 1.0.14. |
| Missing cryptographic key commitment in the Amazon S3 Encryption Client for Java may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade Amazon S3 Encryption Client for Java to version 4.0.0 or later. |
| HCL DRYiCE Optibot Reset Station is impacted by insecure encryption of security questions. This could allow an attacker with access to the database to recover some or all encrypted values. |
| Due to outdated Hash algorithm, HCL Glovius Cloud could allow attackers to guess the input data using brute-force or dictionary attacks efficiently using modern hardware such as GPUs or ASICs |