| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Mitrastar GPT-2741GNAC-N2 devices are provided with access through ssh into a restricted default shell.The command "deviceinfo show file" is supposed to be used from restricted shell to show files and directories. By providing " /bin/sh" (quotes included) to the argument of this command will drop a root shell. |
| SAP GUI for Windows allows an unauthenticated attacker to exploit insecure obfuscation algorithms used by the GuiXT application to store user credentials. While this issue does not impact the Integrity or Availability of the application, it may have a Low impact on the Confidentiality of data. |
| SAP GUI for Windows may allow the leak of NTML hashes when specific ABAP frontend services are called with UNC paths. For a successful attack, the attacker needs developer authorization in a specific Application Server ABAP to make changes in the code, and the victim needs to execute by using SAP GUI for Windows. This could trigger automatic NTLM authentication, potentially exposing hashed credentials to an attacker. As a result, it has a high impact on the confidentiality. |
| A flaw was found in Quay, where Quay's database is stored in plain text in mirror-registry on Jinja's config.yaml file. This issue leaves the possibility of a malicious actor with access to this file to gain access to Quay's Redis instance. |
| A flaw was found in how Quay's database is stored in plain-text in mirror-registry on the jinja's config.yaml file. This flaw allows a malicious actor with access to this file to gain access to Quay's database. |
| WF2220 exposes endpoint /cgi-bin-igd/netcore_get.cgi that returns configuration of the device to unauthorized users. Returned configuration includes cleartext password.
The vendor was contacted early about this disclosure but did not respond in any way. |
| The vulnerability affects Ignition SCADA applications where Python
scripting is utilized for automation purposes. The vulnerability arises
from the absence of proper security controls that restrict which Python
libraries can be imported and executed within the scripting environment.
The core issue lies in the Ignition service account having system
permissions beyond what an Ignition privileged user requires. When an
authenticated administrator uploads a malicious project file containing
Python scripts with bind shell capabilities, the application executes
these scripts with the same privileges as the Ignition Gateway process,
which typically runs with SYSTEM-level permissions on Windows.
Alternative code execution patterns could lead to similar results. |
| Westermo EDW-100 devices through 2024-05-03 allow an unauthenticated user to download a configuration file containing a cleartext password. NOTE: this is a serial-to-Ethernet converter that should not be placed at the edge of the network. |
| A vulnerability was determined in TaleLin Lin-CMS up to 0.6.0. This affects an unknown part of the file /tests/config.py of the component Tests Folder. This manipulation of the argument username/password causes password in configuration file. The attack is possible to be carried out remotely. The complexity of an attack is rather high. It is indicated that the exploitability is difficult. The exploit has been publicly disclosed and may be utilized. |
| Bosscomm IF740 Firmware versions:11001.7078 & v11001.0000 and System versions: 6.25 & 6.00 were discovered to store passwords in cleartext. |
| runofast Indoor Security Camera for Baby Monitor has a default password of password for the root account. This allows access to the /stream1 URI via the rtsp:// protocol to receive the video and audio stream. |
| Incorrect Access Control vulnerability in ZLMediaKit versions 1.0 through 8.0, allows remote attackers to escalate privileges and obtain sensitive information. The application system enables the http API interface by default and uses the secret parameter method to authenticate the http restful api interface, but the secret is hardcoded by default. |
| Use of hard-coded password issue/vulnerability in SS1 Ver.16.0.0.10 and earlier (Media version:16.0.0a and earlier) allows a remote unauthenticated attacker to view arbitrary files with root privileges. |
| The Single RAN baseband OAM service is intended to run as an unprivileged service. However, it initially starts with root privileges and assigns certain capabilities before dropping to an unprivileged level. The capabilities retained from the root period are considered extensive after the privilege drop and, in theory, could potentially allow actions beyond the intended scope of the OAM service. These actions could include gaining root privileges, accessing root-owned files, modifying them as the file owner, and then returning them to root ownership. This issue has been corrected starting from release 24R1-SR 0.2 MP and later.
Beginning with release 24R1-SR 0.2 MP, the OAM service software capabilities are restricted to the minimum necessary. |
| Screen 5.0.0 when it runs with setuid-root privileges does not drop privileges while operating on a user supplied path. This allows unprivileged users to create files in arbitrary locations with `root` ownership, the invoking user's (real) group ownership and file mode 0644. All data written to the Screen PTY will be logged into this file, allowing to escalate to root privileges |
| A vulnerability was found in SGAI Space1 NAS N1211DS up to 1.0.915. This issue affects the function GET_FACTORY_INFO/GET_USER_INFO of the file /cgi-bin/JSONAPI of the component gsaiagent. The manipulation results in unprotected storage of credentials. The attack can be launched remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Argo Workflows Chart is used to set up argo and its needed dependencies through one command. Prior to 0.44.0, the workflow-role has excessive privileges, the worst being create pods/exec, which will allow kubectl exec into any Pod in the same namespace, i.e. arbitrary code execution within those Pods. If a user can be made to run a malicious template, their whole namespace can be compromised. This affects versions of the argo-workflows Chart that use appVersion: 3.4 and above, which no longer need these permissions for the only available Executor, Emissary. It could also affect users below 3.4 depending on their choice of Executor in those versions. This only affects the Helm Chart and not the upstream manifests. This vulnerability is fixed in 0.44.0. |
| A flaw was found in openshift/builder. This vulnerability allows command injection via path traversal, where a malicious user can execute arbitrary commands on the OpenShift node running the builder container. When using the “Docker” strategy, executable files inside the privileged build container can be overridden using the `spec.source.secrets.secret.destinationDir` attribute of the `BuildConfig` definition. An attacker running code in a privileged container could escalate their permissions on the node running the container. |
| A security flaw has been discovered in Apeman ID71 218.53.203.117. This vulnerability affects unknown code of the file /system/www/system.ini. The manipulation results in hard-coded credentials. The attack may be performed from remote. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way. |
| IBM Common Cryptographic Architecture (CCA) 7.5.52 and 8.4.82 could allow an unauthenticated user to execute arbitrary commands with elevated privileges on the system. |