| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The puppet manifests in the Red Hat openstack-puppet-modules package before 2014.2.13-2 uses a default password of CHANGEME for the pcsd daemon, which allows remote attackers to execute arbitrary shell commands via unspecified vectors. |
| Django 1.8.x before 1.8.16, 1.9.x before 1.9.11, and 1.10.x before 1.10.3 use a hardcoded password for a temporary database user created when running tests with an Oracle database, which makes it easier for remote attackers to obtain access to the database server by leveraging failure to manually specify a password in the database settings TEST dictionary. |
| NETGEAR Arlo base stations with firmware 1.7.5_6178 and earlier, Arlo Q devices with firmware 1.8.0_5551 and earlier, and Arlo Q Plus devices with firmware 1.8.1_6094 and earlier have a default password of 12345678, which makes it easier for remote attackers to obtain access after a factory reset or in a factory configuration. |
| VMware Photos OS OVA 1.0 before 2016-08-14 has a default SSH public key in an authorized_keys file, which allows remote attackers to obtain SSH access by leveraging knowledge of the private key. |
| The trove service user in (1) Openstack deployment (aka crowbar-openstack) and (2) Trove Barclamp (aka barclamp-trove and crowbar-barclamp-trove) in the Crowbar Framework has a default password, which makes it easier for remote attackers to obtain access via unspecified vectors. |
| The rsyncd server in Fortinet FortiWLC 6.1-2-29 and earlier, 7.0-9-1, 7.0-10-0, 8.0-5-0, 8.1-2-0, and 8.2-4-0 has a hardcoded rsync account, which allows remote attackers to read or write to arbitrary files via unspecified vectors. |
| SAP Download Manager 2.1.142 and earlier generates an encryption key from a small key space on Windows and Mac systems, which allows context-dependent attackers to obtain sensitive configuration information by leveraging knowledge of a hardcoded key in the program code and a computer BIOS serial number, aka SAP Security Note 2282338. |
| The TripleO Heat templates (tripleo-heat-templates), as used in Red Hat Enterprise Linux OpenStack Platform 7.0, do not properly use the configured RabbitMQ credentials, which makes it easier for remote attackers to obtain access to services in deployed overclouds by leveraging knowledge of the default credentials. |
| IBM BigFix Remote Control before 9.1.3 allows local users to discover hardcoded credentials via unspecified vectors. |
| Windows Local Security Authority (LSA) Elevation of Privilege Vulnerability |
| Moxa EDR-G903 series routers with firmware before 2.11 have a hardcoded account, which allows remote attackers to obtain unspecified device access via unknown vectors. |
| Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568. |
| Red Hat livecd-tools before 13.4.4, 17.x before 17.17, 18.x before 18.16, and 19.x before 19.3, when a rootpw directive is not set in a Kickstart file, sets the root user password to empty, which allows local users to gain privileges. |
| Linksys WAP54Gv3 firmware 3.04.03 and earlier uses a hard-coded username (Gemtek) and password (gemtekswd) for a debug interface for certain web pages, which allows remote attackers to execute arbitrary commands via the (1) data1, (2) data2, or (3) data3 parameters to (a) Debug_command_page.asp and (b) debug.cgi. |
| The installation script in Katello 1.0 and earlier does not properly generate the Application.config.secret_token value, which causes each default installation to have the same secret token, and allows remote attackers to authenticate to the CloudForms System Engine web interface as an arbitrary user by creating a cookie using the default secret_token. |
| auth_db_config.py in Pyftpd 0.8.4 contains hard-coded usernames and passwords for the (1) test, (2) user, and (3) roxon accounts, which allows remote attackers to read arbitrary files from the FTP server. |
| A CWE-798 “Use of Hard-coded Credentials” vulnerability in the MariaDB database of the web application allows a remote unauthenticated attacker to access the database service and all included data with the same privileges of the web application. This issue affects: AiLux imx6 bundle below version imx6_1.0.7-2. |
| ISOS firmwares from versions 1.81 to 2.00 contain hardcoded credentials from embedded StreamX installer that integrators are not forced to change.
|
| Merit LILIN AH55B04 & AH55B08 DVR firm has hard-coded administrator credentials. An unauthenticated remote attacker can use these credentials to log in administrator page, to manipulate system or disrupt service. |
|
In the DES implementation, the affected product versions use a default key for encryption. Successful exploitation allows an attacker to obtain sensitive information and gain access to the network elements that are managed by the affected products versions.
This issue affects
* FOXMAN-UN product: FOXMAN-UN R16A, FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C;
* UNEM product: UNEM R16A, UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C.
List of CPEs:
* cpe:2.3:a:hitachienergy:foxman-un:R16A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R16A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*
|