| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Use of Hard-coded Credentials in GitHub repository alextselegidis/easyappointments prior to 1.5.0. |
| Use of Hard-coded Password vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to obtain a hard-coded password and access to the module via FTP. |
| A Hard Coded Admin Credentials issue in the Web-UI Admin Panel in Propius MachineSelector 6.6.0 and 6.6.1 allows remote attackers to gain access to the admin panel Propiusadmin.php, which allows taking control of the affected system. |
| A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)). The affected devices contain a hard-coded ID in the SSH `authorized_keys` configuration file. An attacker with knowledge of the corresponding private key could login to the device via SSH. Only devices with activated debug support are affected. |
| MGT-COMMERCE CloudPanel ships with a static SSL certificate to encrypt communications to the administrative interface, shared across every installation of CloudPanel. This behavior was observed in version 2.2.0. There has been no indication from the vendor this has been addressed in version 2.2.1. |
| Hard-coded credentials in Web-UI of multiple VARTA Storage products in multiple versions allows an unauthorized attacker to gain administrative access to the Web-UI via network. |
| SolarWinds Web Help Desk was found to have a hardcoded cryptographic key that could allow the disclosure of sensitive information from the software. |
| PanIndex is a network disk directory index. In Panindex prior to version 3.1.3, a hard-coded JWT key `PanIndex` is used. An attacker can use the hard-coded JWT key to sign JWT token and perform any actions as a user with admin privileges. Version 3.1.3 has a patch for the issue. As a workaround, one may change the JWT key in the source code before compiling the project.
|
| DataEase is an open source data visualization analysis tool. Prior to 2.10.2, DataEase allows attackers to forge jwt and take over services. The JWT secret is hardcoded in the code, and the UID and OID are hardcoded. The vulnerability has been fixed in v2.10.2. |
| Rocket Software UniData versions prior to 8.2.4 build 3003 and UniVerse versions prior to 11.3.5 build 1001 or 12.2.1 build 2002 suffer from an authentication bypass vulnerability, where a special username with a deterministic password can be leveraged to bypass authentication checks and execute OS commands as the root user. |
| Use of hard-coded MSSQL credentials in PerkinElmer ProcessPlus on Windows allows an attacker to login remove on all prone installations.This issue affects ProcessPlus: through 1.11.6507.0. |
| A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The affected devices contain the hash of the root password in a hard-coded form, which could be exploited for UART console login to the device. An attacker with direct physical access could exploit this vulnerability. |
| your_spotify is an open source, self hosted Spotify tracking dashboard. YourSpotify versions < 1.8.0 use a hardcoded JSON Web Token (JWT) secret to sign authentication tokens. Attackers can use this well-known value to forge valid authentication tokens for arbitrary users. This vulnerability allows attackers to bypass authentication and authenticate as arbitrary YourSpotify users, including admin users. This issue has been addressed in version 1.8.0. Users are advised to upgrade. There are no known workarounds for this vulnerability. |
| Android App 'Wolt Delivery: Food and more' version 4.27.2 and earlier uses hard-coded credentials (API key for an external service), which may allow a local attacker to obtain the hard-coded API key via reverse-engineering the application binary. |
| The SolarWinds Access Rights Manager was found to contain a hard-coded credential authentication bypass vulnerability. If exploited, this vulnerability allows access to the RabbitMQ management console.
We thank Trend Micro Zero Day Initiative (ZDI) for its ongoing partnership in coordinating with SolarWinds on responsible disclosure of this and other potential vulnerabilities. |
| ONTAP Select Deploy administration utility versions 9.12.1.x,
9.13.1.x and 9.14.1.x contain hard-coded credentials that could allow an
attacker to view Deploy configuration information and modify the
account credentials.
|
| TP-Link Tapo C310 1.3.0 devices allow access to the RTSP video feed via credentials of User --- and Password TPL075526460603. |
| Electra Central AC unit – Hardcoded Credentials in unspecified code used by the unit. |
| Use of Hard-coded Credentials in GitHub repository nuxtlabs/github-module prior to 1.6.2. |
| A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) |