| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Swatchly – WooCommerce Variation Swatches for Products (product attributes: Image swatch, Color swatches, Label swatches) plugin for WordPress is vulnerable to unauthorized modification of data due to a missing capability check on the ajax_dismiss function in versions 1.2.8 to 1.4.0. This makes it possible for authenticated attackers, with Subscriber-level access and above, to update option values to 1/true on the WordPress site. This can be leveraged to update an option that would create an error on the site and deny access to legitimate users or be used to set some values to true, such as registration. |
| The device uses a weak hashing alghorithm to create the password hash. Hence, a matching password can be easily calculated by an attacker. This impacts the security and the integrity of the device. |
| An incomplete fix has been identified for CVE-2025-23084 in Node.js, specifically affecting Windows device names like CON, PRN, and AUX.
This vulnerability affects Windows users of `path.join` API. |
| An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network. |
| An Improper Access Control could allow a malicious actor authenticated in the API of certain UniFi Connect devices to enable Android Debug Bridge (ADB) and make unsupported changes to the system.
Affected Products:
UniFi Connect EV Station Pro (Version 1.5.18 and earlier)
UniFi Connect Display (Version 1.9.324 and earlier)
UniFi Connect Display Cast (Version 1.9.301 and earlier)
UniFi Connect Display Cast Pro (Version 1.0.78 and earlier)
UniFi Connect Display Cast Lite (Version 1.0.3 and earlier)
Mitigation:
Update UniFi Connect EV Station Pro to Version 1.5.27 or later
Update UniFi Connect Display to Version 1.13.6 or later
Update UniFi Connect Display Cast to Version 1.10.3 or later
Update UniFi Connect Display Cast Pro to Version 1.0.83 or later
Update UniFi Connect Display Cast Lite to Version 1.1.3 or later |
| A Missing Authentication for Critical Function vulnerability in the UniFi Connect EV Station Pro may allow a malicious actor with physical or adjacent access to perform an unauthorized factory reset.
Affected Products:
UniFi Connect EV Station Pro (Version 1.5.18 and earlier)
Mitigation:
Update UniFi Connect EV Station Pro to Version 1.5.27 or later |
| An Improper Access Control could allow a malicious actor authenticated in the API of certain UniFi Connect Display Cast devices to make unsupported changes to the system.
Affected Products:
UniFi Connect Display Cast (Version 1.10.3 and earlier)
UniFi Connect Display Cast Pro (Version 1.0.89 and earlier)
UniFi Connect Display Cast Lite (Version 1.0.3 and earlier)
Mitigation:
Update UniFi Connect Display Cast to Version 1.10.7 or later
Update UniFi Connect Display Cast Pro to Version 1.0.94 or later
Update UniFi Connect Display Cast Lite to Version 1.1.8 or later |
| Multiple Incorrect Permission Assignment for Critical Resource in UISP Application may allow a malicious actor with certain permissions to escalate privileges. |
| Sitecore Experience Manager (XM) and Experience Platform (XP) 10.4 before KB1002844 allow remote code execution through insecure deserialization. |
| Zabbix Agent 2 smartctl plugin does not properly sanitize smart.disk.get parameters, allowing an attacker to inject unexpected arguments into the smartctl command. In Zabbix 5.0 this allows for remote code execution. |
| In Zabbix Agent and Agent 2 on Windows, the OpenSSL configuration file is loaded from a path writable by low-privileged users, allowing malicious modification and potential local privilege escalation by injecting a DLL. |
| Incorrect default permissions for the Intel(R) Processor Identification Utility before version 8.0.43 within Ring 3: User Applications may allow an escalation of privilege. System software adversary with an authenticated user combined with a high complexity attack may enable local code execution. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires active user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts. |
| Uncontrolled resource consumption for some Gaudi software before version 1.21.0 within Ring 3: User Applications may allow a denial of service. System software adversary with an authenticated user combined with a low complexity attack may enable denial of service. This result may potentially occur via local access when attack requirements are not present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (none), integrity (none) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts. |
| A vulnerability classified as critical was found in H3C Magic NX15, Magic NX30 Pro, Magic NX400, Magic R3010 and Magic BE18000 up to V100R014. Affected by this vulnerability is an unknown functionality of the file /api/login/auth of the component HTTP POST Request Handler. The manipulation leads to command injection. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. |
| Uncontrolled resource consumption for some Edge Orchestrator software before version 24.11.1 for Intel(R) Tiber(TM) Edge Platform may allow an authenticated user to potentially enable denial of service via adjacent access. |
| A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network. |
| CWE-282 "Improper Ownership Management" in GE Vernova EnerVista UR Setup allows Authentication Bypass.
The software's startup authentication can be disabled by altering a Windows registry setting that any user can modify. |
| Use of Hard-coded Credentials vulnerability in GE Vernova EnerVista UR Setup allows Privilege Escalation. The local user database is encrypted using an hardcoded password retrievable by an attacker analyzing the application code. |
| Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker may perform a man-in-the-middle attack on the network. |
| Insufficient Verification of Data Authenticity vulnerability in GE Vernova UR IED family devices allows an authenticated user to install a modified firmware.
The firmware signature verification is enforced only on the client-side dedicated software Enervista UR Setup, allowing the integration check to be bypassed. |