Export limit exceeded: 352753 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (2257 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-12004 1 Mediawiki 1 Mediawiki 2026-04-15 N/A
Incorrect Permission Assignment for Critical Resource vulnerability in The Wikimedia Foundation Mediawiki - Lockdown Extension allows Privilege Abuse. Fixed in Mediawiki Core Action APIThis issue affects Mediawiki - Lockdown Extension: from master before 1.42.
CVE-2025-12108 1 Survision 1 License Plate Recognition Camera 2026-04-15 N/A
The Survision LPR Camera system does not enforce password protection by default. This allows access to the configuration wizard immediately without a login prompt or credentials check.
CVE-2025-12140 1 Simple Sa 1 Wirtualna Uczelnia 2026-04-15 N/A
The application contains an insecure 'redirectToUrl' mechanism that incorrectly processes the value of the 'redirectUrlParameter' parameter. The application interprets the entered string of characters as a Java expression, allowing an unauthenticated attacer to perform arbitrary code execution. This issue was fixed in version wu#2016.1.5513#0#20251014_113353
CVE-2025-12414 1 Google 1 Cloud Looker 2026-04-15 N/A
An attacker could take over a Looker account in a Looker instance configured with OIDC authentication, due to email address string normalization.Looker-hosted and Self-hosted were found to be vulnerable. This issue has already been mitigated for Looker-hosted. Self-hosted instances must be upgraded as soon as possible. This vulnerability has been patched in all supported versions of Self-hosted. The versions below have all been updated to protect from this vulnerability. You can download these versions at the Looker download page https://download.looker.com/ : * 24.12.100+ * 24.18.193+ * 25.0.69+ * 25.6.57+ * 25.8.39+ * 25.10.22+ * 25.12.0+
CVE-2025-12592 1 Vivotek 1 Camera 2026-04-15 N/A
Legacy Vivotek Device firmware uses default credetials for the root and user login accounts.
CVE-2025-1265 2026-04-15 9.9 Critical
An OS command injection vulnerability exists in Vinci Protocol Analyzer that could allow an attacker to escalate privileges and perform code execution on affected system.
CVE-2025-1087 2026-04-15 N/A
Kong Insomnia Desktop Application before 11.0.2 contains a template injection vulnerability that allows attackers to execute arbitrary code. The vulnerability exists due to insufficient validation of user-supplied input when processing template strings, which can lead to arbitrary JavaScript execution in the context of the application.
CVE-2025-10870 1 Dial 1 Centrosnet 2026-04-15 N/A
SQL injection vulnerability in DIAL's CentrosNet v2.64. Allows an attacker to retrieve, create, update, and delete databases by sending POST and GET requests with the 'ultralogin' parameter in '/centrosnet/ultralogin.php'.
CVE-2025-10910 2026-04-15 N/A
A flaw in the binding process of Govee’s cloud platform and devices allows a remote attacker to bind an existing, online Govee device to the attacker’s account, resulting in full control of the device and removal of the device from its legitimate owner’s account. The server‑side API allows device association using a set of identifiers: "device", "sku", "type", and a client‑computed "value", that are not cryptographically bound to a secret originating from the device itself. The vulnerability has been verified for the Govee H6056 - lamp device in firmware version 1.08.13, but may affect also other Govee cloud‑connected devices. The vendor is investigating other potentially affected models. The vendor has deployed server-side security enhancements and automatic firmware updates for model H6056. Most of H6056 devices have been successfully patched through automatic updates. Remaining H6056 users with upgradeable hardware versions must manually update firmware through the Govee Home app while keeping their device WiFi-connected. Users should open the Govee Home app, tap their H6056 device card to enter the device details page, tap the settings icon in the upper right corner, navigate to Device Information section (Firmware Version), and tap the Update button to install the security patch immediately. Govee H6056 devices with hardware versions 1.00.10 or 1.00.11 cannot receive firmware update due to hardware limitations.
CVE-2025-11126 1 Apeman 1 Apeman 2026-04-15 9.8 Critical
A security flaw has been discovered in Apeman ID71 218.53.203.117. This vulnerability affects unknown code of the file /system/www/system.ini. The manipulation results in hard-coded credentials. The attack may be performed from remote. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-11221 1 Gtone 1 Changeflow 2026-04-15 8.8 High
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Unrestricted Upload of File with Dangerous Type vulnerability in GTONE ChangeFlow allows Path Traversal, Accessing Functionality Not Properly Constrained by ACLs.This issue affects ChangeFlow: from All versions through v9.0.1.1.
CVE-2025-11534 1 Raisecom 1 Rax701 2026-04-15 N/A
The affected Raisecom devices allow SSH sessions to be established without completing user authentication. This could allow attackers to gain shell access without valid credentials.
CVE-2025-11545 2026-04-15 N/A
Exposure of Sensitive System Information to an Unauthorized Control Sphere vulnerability in Sharp Display Solutions projectors allows a attacker may improperly access the HTTP server and execute arbitrary actions.
CVE-2025-11462 2 Amazon, Apple 2 Aws Client Vpn, Macos 2026-04-15 7.8 High
Improper Link Resolution Before File Access in the AWS VPN Client for macOS versions 1.3.2- 5.2.0 allows a local user to execute code with elevated privileges. Insufficient validation checks on the log destination directory during log rotation could allow a non-administrator user to create a symlink from a client log file to a privileged location. On log rotation, this could lead to code execution with root privileges if the user made crafted API calls which injected arbitrary code into the log file. We recommend users upgrade to AWS VPN Client for macOS 5.2.1 or the latest version.
CVE-2025-11544 2026-04-15 N/A
Improper Validation of Integrity Check Value vulnerability in Sharp Display Solutions projectors allows a attacker may create and run unauthorized firmware.
CVE-2025-11546 2 Linux, Nec 5 Linux, Clusterpro X, Clusterpro X Singleserversafe and 2 more 2026-04-15 N/A
CLUSTERPRO X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 and EXPRESSCLUSTER X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, CLUSTERPRO X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, EXPRESSCLUSTER X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 allows an attacker sends specially crafted network packets to the product, arbitrary OS commands may be executed without authentication.
CVE-2025-11548 1 Ibi 1 Webfocus Business Intelligence 2026-04-15 N/A
A remote, unauthenticated privilege escalation in ibi WebFOCUS allows an attacker to gain administrative access to the application which may lead to unauthenticated Remote Code Execution
CVE-2025-1077 2026-04-15 N/A
A security vulnerability has been identified in the IBL Software Engineering Visual Weather and derived products (NAMIS, Aero Weather, Satellite Weather). The vulnerability is present in the Product Delivery Service (PDS) component in specific server configurations where the PDS pipeline utilizes the IPDS pipeline with Message Editor Output Filters enabled. A remote unauthenticated attacker can exploit this vulnerability to send unauthenticated requests to execute the IPDS pipeline with specially crafted Form Properties, enabling remote execution of arbitrary Python code. This vulnerability could lead to a full system compromise of the affected server, particularly if Visual Weather services are run under a privileged user account—contrary to the documented installation best practices. Upgrade to the patched versions 7.3.10 (or higher), 8.6.0 (or higher).
CVE-2025-10729 1 Qt 1 Qt 2026-04-15 8.6 High
The module will parse a <pattern> node which is not a child of a structural node. The node will be deleted after creation but might be accessed later leading to a use after free.
CVE-2025-10264 1 Digiever 7 Ds-1200, Ds-16x00, Ds-2100 and 4 more 2026-04-15 10 Critical
Certain models of NVR developed by Digiever has an Exposure of Sensitive Information vulnerability, allowing unauthenticated remoter attackers to access the system configuration file and obtain plaintext credentials of the NVR and its connected cameras.