Search Results (20514 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-25568 2026-04-15 8.8 High
OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent unauthenticated attacker to execute arbitrary OS commands by sending a specially crafted request to the product. Affected products and versions are as follows: WRC-X3200GST3-B v1.25 and earlier, WRC-G01-W v1.24 and earlier, and WMC-X1800GST-B v1.41 and earlier. Note that WMC-X1800GST-B is also included in e-Mesh Starter Kit "WMC-2LX-B".
CVE-2024-25579 1 Elecom 10 Wmc-x1800gst-b Firmware, Wrc-1167gs2-b Firmware, Wrc-1167gs2h-b Firmware and 7 more 2026-04-15 6.8 Medium
OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent attacker with an administrative privilege to execute arbitrary OS commands by sending a specially crafted request to the product. Note that WMC-X1800GST-B is also included in e-Mesh Starter Kit "WMC-2LX-B".
CVE-2024-26258 1 Elecom 2 Wrc-g01-w Firmware, Wrc-x3200gst3-b Firmware 2026-04-15 7.1 High
OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent attacker with credentials to execute arbitrary OS commands by sending a specially crafted request to the product.
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-28748 1 Ifm 2 Smart Plc Ac14xx Firmware, Smart Plc Ac4xxs Firmware 2026-04-15 7.2 High
A remote attacker with high privileges may use a reading file function to inject OS commands.
CVE-2024-28749 1 Ifm 2 Smart Plc Ac14xx Firmware, Smart Plc Ac4xxs Firmware 2026-04-15 7.2 High
A remote attacker with high privileges may use a writing file function to inject OS commands.
CVE-2024-28750 1 Ifm 2 Smart Plc Ac14xx Firmware, Smart Plc Ac4xxs Firmware 2026-04-15 7.2 High
A remote attacker with high privileges may use a deleting file function to inject OS commands.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-31408 2026-04-15 N/A
OS command injection vulnerability exists in AIPHONE IX SYSTEM and IXG SYSTEM. A network-adjacent authenticated attacker may execute an arbitrary OS command with root privileges by sending a specially crafted request.
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-3298 2026-04-15 7.8 High
Out-Of-Bounds Write and Type Confusion vulnerabilities exist in the file reading procedure in eDrawings from Release SOLIDWORKS 2023 through Release SOLIDWORKS 2024. These vulnerabilities could allow an attacker to execute arbitrary code while opening a specially crafted DWG or DXF. NOTE: this vulnerability was SPLIT from CVE-2024-1847.
CVE-2024-33008 2026-04-15 4.9 Medium
SAP Replication Server allows an attacker to use gateway for executing some commands to RSSD. This could result in crashing the Replication Server due to memory corruption with high impact on Availability of the system.
CVE-2025-54314 2026-04-15 2.8 Low
Thor before 1.4.0 can construct an unsafe shell command from library input. NOTE: this is disputed by the Supplier because "the method that was fixed can only be used with arguments that are controlled by Thor, and there is no way an attacker can take control of those arguments."
CVE-2025-2172 1 Aviatrix 1 Controller 2026-04-15 N/A
Aviatrix Controller versions prior to 7.1.4208, 7.2.5090, and 8.0.0 fail to sanitize user input prior to passing the input to command line utilities, allowing command injection via special characters in filenames
CVE-2025-54763 1 Centurysys 5 Futurenet Ip-k Series, Futurenet Ma-e300 Series, Futurenet Ma-p Series and 2 more 2026-04-15 7.2 High
FutureNet MA and IP-K series provided by Century Systems Co., Ltd. contain an OS command Injection vulnerability. A user who logs in to the Web UI of the product may execute an arbitrary OS command.
CVE-2024-4301 2026-04-15 8.8 High
N-Reporter and N-Cloud, products of the N-Partner, have an OS Command Injection vulnerability. Remote attackers with normal user privilege can execute arbitrary system commands by manipulating user inputs on a specific page.
CVE-2024-33218 1 Asus 1 Usb3.0 Boost Storage Driver 2026-04-15 7.8 High
An issue in the component AsUpIO64.sys of ASUSTeK Computer Inc ASUS USB 3.0 Boost Storage Driver 5.30.20.0 allows attackers to escalate privileges and execute arbitrary code via sending crafted IOCTL requests.
CVE-2024-33221 1 Asus 1 Bios Flash Driver 2026-04-15 7.8 High
An issue in the component AsusBSItf.sys of ASUSTeK Computer Inc ASUS BIOS Flash Driver v3.2.12.0 allows attackers to escalate privileges and execute arbitrary code via sending crafted IOCTL requests.
CVE-2024-33222 1 Asus 1 Atszio Driver 2026-04-15 8.4 High
An issue in the component ATSZIO64.sys of ASUSTeK Computer Inc ASUS ATSZIO Driver v0.2.1.7 allows attackers to escalate privileges and execute arbitrary code via sending crafted IOCTL requests.