Export limit exceeded: 20518 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (20518 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-12050 | 1 Insyde | 1 Insydeh2o | 2026-04-15 | 7.8 High |
| The drivers in the tool packages use RTL_QUERY_REGISTRY_DIRECT flag to read a registry value to which an untrusted user-mode application may be able to cause a buffer overflow. | ||||
| CVE-2025-48047 | 2026-04-15 | N/A | ||
| An authenticated user can perform command injection via unsanitized input to the NetFax Server’s ping functionality via the /test.php endpoint. | ||||
| CVE-2024-34013 | 1 Acronis | 1 True Image | 2026-04-15 | N/A |
| Local privilege escalation due to OS command injection vulnerability. The following products are affected: Acronis True Image (macOS) before build 41396, Acronis True Image OEM (macOS) before build 42571. | ||||
| CVE-2025-9996 | 1 Schneider-electric | 1 Blmon | 2026-04-15 | N/A |
| CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session. | ||||
| CVE-2025-22469 | 1 Sato | 4 Cl4nx-j Plus, Cl4nx Plus, Cl6nx-j Plus and 1 more | 2026-04-15 | N/A |
| OS command injection vulnerability exists in CL4/6NX Plus and CL4/6NX-J Plus (Japan model) with the firmware versions prior to 1.15.5-r1. An arbitrary OS command may be executed on the system with a certain non-administrative user privilege. | ||||
| CVE-2025-10101 | 2 Apple, Avast | 2 Macos, Antivirus | 2026-04-15 | 8.1 High |
| Heap-based Buffer Overflow, Out-of-bounds Write vulnerability in Avast Antivirus on MacOS of a crafted Mach-O file may allow Local Execution of Code or Denial of Service of antivirus protection. This issue affects Antivirus: from 15.7 before 3.9.2025. | ||||
| CVE-2025-52379 | 2026-04-15 | 5.4 Medium | ||
| Nexxt Solutions NCM-X1800 Mesh Router firmware UV1.2.7 and below contains an authenticated command injection vulnerability in the firmware update feature. The /web/um_fileName_set.cgi and /web/um_web_upgrade.cgi endpoints fail to properly sanitize the upgradeFileName parameter, allowing authenticated attackers to execute arbitrary OS commands on the device, resulting in remote code execution. | ||||
| CVE-2025-3189 | 2026-04-15 | N/A | ||
| Stored Cross-Site Scripting (XSS) in DoWISP in versions prior to 1.16.2.50, which consists of an stored XSS through the upload of a profile picture in SVG format with malicious Javascript code in it. | ||||
| CVE-2024-32850 | 1 Seiko-sol | 2 Skybridge Basic Mb-a130 Firmware, Skybridge Mb-a110 Firmware | 2026-04-15 | 9.8 Critical |
| Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege. | ||||
| CVE-2024-43653 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2025-3154 | 1 Xpdf | 1 Xpdf | 2026-04-15 | N/A |
| Out-of-bounds array write in Xpdf 4.05 and earlier, triggered by an invalid VerticesPerRow value in a PDF shading dictionary. | ||||
| CVE-2024-31162 | 1 Asus | 1 Download Master | 2026-04-15 | 7.2 High |
| The specific function parameter of ASUS Download Master does not properly filter user input. An unauthenticated remote attacker with administrative privileges can exploit this vulnerability to execute arbitrary system commands on the device. | ||||
| CVE-2025-34037 | 1 Linksys | 6 E1000, E1200, E1500 and 3 more | 2026-04-15 | N/A |
| An OS command injection vulnerability exists in various models of E-Series Linksys routers via the /tmUnblock.cgi and /hndUnblock.cgi endpoints over HTTP on port 8080. The CGI scripts improperly process user-supplied input passed to the ttcp_ip parameter without sanitization, allowing unauthenticated attackers to inject shell commands. This vulnerability was reported to be exploited in the wild by the "TheMoon" worm in 2014 to deploy a MIPS ELF payload, enabling arbitrary code execution on the router. Additionally, this vulnerability may affect other Linksys products to include, but not limited to, WAG/WAP/WES/WET/WRT-series router models and Wireless-N access points and routers. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-06 UTC. | ||||
| CVE-2025-0236 | 2026-04-15 | 5.3 Medium | ||
| Out-of-bounds vulnerability in slope processing during curve rendering in Generic PCL6 V4 Printer Driver / Generic UFR II V4 Printer Driver / Generic LIPSLX V4 Printer Driver. | ||||
| CVE-2025-0235 | 2026-04-15 | 5.3 Medium | ||
| Out-of-bounds vulnerability due to improper memory release during image rendering in Generic PCL6 V4 Printer Driver / Generic UFR II V4 Printer Driver / Generic LIPSLX V4 Printer Driver. | ||||
| CVE-2025-11202 | 1 Win-cli-mcp-server | 1 Win-cli-mcp-server | 2026-04-15 | N/A |
| win-cli-mcp-server resolveCommandPath Command Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of win-cli-mcp-server. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of the resolveCommandPath method. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the service account. Was ZDI-CAN-27787. | ||||
| CVE-2024-40895 | 2026-04-15 | 6.4 Medium | ||
| FFRI AMC versions 3.4.0 to 3.5.3 and some OEM products that implement/bundle FFRI AMC versions 3.4.0 to 3.5.3 allow a remote unauthenticated attacker to execute arbitrary OS commands when certain conditions are met in an environment where the notification program setting is enabled and the executable file path is set to a batch file (.bat) or command file (.cmd) extension. | ||||
| CVE-2024-5241 | 2026-04-15 | 4.7 Medium | ||
| A vulnerability was found in Huashi Private Cloud CDN Live Streaming Acceleration Server up to 20240520. It has been classified as critical. Affected is an unknown function of the file /manager/ipconfig_new.php. The manipulation of the argument dev leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-265992. | ||||
| CVE-2025-34152 | 1 Shenzhen Aitemi | 2 M300, M300 Wifi Repeater | 2026-04-15 | N/A |
| An unauthenticated OS command injection vulnerability exists in the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02) via the 'time' parameter of the '/protocol.csp?' endpoint. The input is processed by the internal date '-s' command without rebooting or disrupting HTTP service. Unlike other injection points, this vector allows remote compromise without triggering visible configuration changes. | ||||
| CVE-2024-43655 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||